Review




Structured Review

Mimetas Inc renal chip array
Renal Chip Array, supplied by Mimetas Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/array+chip+renal/pmc12805313-461-3-9
Average 86 stars, based on 1 article reviews
renal chip array - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

Impedance Spectroscopy:

Article Title: The Use of Sensors in Blood-Brain Barrier-on-a-Chip Devices: Current Practice and Future Directions.
Article Snippet: A wide range of BBBoCs Biosensors 2023, 13, 357 5 of 17 utilize TEER and EIS sensors for monitoring the overall tightness or disruption of the barrier integrity (Table 1). two-compartment vertical chip 4 Pt film electrodes, custom impedance analyzer with AD5933 chip (Analog Devices) co-culture: primary human brain endothelial cells, pericytes, astrocytes [22,23] two-compartment vertical chip 4 Pt wire electrodes, SP-300 potentiostat (Bio-Logic Science Instruments), HP4194A impedance analyzer (Hewlett Packard) hCMEC/D3 human brain endothelial cell line [24] two-compartment vertical chip 2 Pt wire electrodes, PGSTAT302N potentiostat with FRA32M frequency response analysis module (Metrohm Autolab BV) bEnd.3 mouse brain endothelial cell line [25] two-compartment vertical chip 4 Au film electrodes, PGstat128N (Metrohm Autolab BV) co-culture: human iPSC derived endothelial cell, human brain pericytes, astrocytes [26] two-compartment vertical chip 2 Ag/AgCl wire electrodes, E4980AL/032 LCR meter (Keysight Technologies) co-culture: human iPSC derived endothelial cell, human astrocytes [27] Biosensors 2023, 13, 357 6 of 17 two-compartment vertical chip 4 Pt wire electrodes, HF2IS impedance spectroscope, HF2LI lock-in amplifier (Zurich Instruments) hCMEC/D3 human brain endothelial cell line [28] two-compartment horizontal multiplexed chip (Organoplate) stainless-steel multiplexed pair-electrodes, MI-OT-1 OrganoTEER device (MIMETAS) co-culture: human primary brain endothelial cells, astrocytes, iPSC derived neurons [29] parallel tubular channel horizontal chip 2 wire electrodes, Stingray DS1M12 USB oscilloscope and signal generator (USB Instruments) co-culture: hCMEC/D3 human brain endothelial cell line, human astrocytes [30] Streaming potential two-compartment vertical chip 2 Ag/AgCl wire electrodes, SR560 voltage pre-amplifier (Stanford Research Systems), Wave Ace digital oscilloscope (Teledyne LeCroy) hCMEC/D3 human brain endothelial cell line [31] Abbreviation: ERS, electrical resistance system; EVOM, Epithelial Voltohmmeter; HUVEC, human umbilical vein endothelial cells; iPSC, induced pluripotent stem cell; MEA, multi-electrode array; SC, stem cell; WPI, World Precision Instruments.

Disruption:

Article Title: The Use of Sensors in Blood-Brain Barrier-on-a-Chip Devices: Current Practice and Future Directions.
Article Snippet: A wide range of BBBoCs Biosensors 2023, 13, 357 5 of 17 utilize TEER and EIS sensors for monitoring the overall tightness or disruption of the barrier integrity (Table 1). two-compartment vertical chip 4 Pt film electrodes, custom impedance analyzer with AD5933 chip (Analog Devices) co-culture: primary human brain endothelial cells, pericytes, astrocytes [22,23] two-compartment vertical chip 4 Pt wire electrodes, SP-300 potentiostat (Bio-Logic Science Instruments), HP4194A impedance analyzer (Hewlett Packard) hCMEC/D3 human brain endothelial cell line [24] two-compartment vertical chip 2 Pt wire electrodes, PGSTAT302N potentiostat with FRA32M frequency response analysis module (Metrohm Autolab BV) bEnd.3 mouse brain endothelial cell line [25] two-compartment vertical chip 4 Au film electrodes, PGstat128N (Metrohm Autolab BV) co-culture: human iPSC derived endothelial cell, human brain pericytes, astrocytes [26] two-compartment vertical chip 2 Ag/AgCl wire electrodes, E4980AL/032 LCR meter (Keysight Technologies) co-culture: human iPSC derived endothelial cell, human astrocytes [27] Biosensors 2023, 13, 357 6 of 17 two-compartment vertical chip 4 Pt wire electrodes, HF2IS impedance spectroscope, HF2LI lock-in amplifier (Zurich Instruments) hCMEC/D3 human brain endothelial cell line [28] two-compartment horizontal multiplexed chip (Organoplate) stainless-steel multiplexed pair-electrodes, MI-OT-1 OrganoTEER device (MIMETAS) co-culture: human primary brain endothelial cells, astrocytes, iPSC derived neurons [29] parallel tubular channel horizontal chip 2 wire electrodes, Stingray DS1M12 USB oscilloscope and signal generator (USB Instruments) co-culture: hCMEC/D3 human brain endothelial cell line, human astrocytes [30] Streaming potential two-compartment vertical chip 2 Ag/AgCl wire electrodes, SR560 voltage pre-amplifier (Stanford Research Systems), Wave Ace digital oscilloscope (Teledyne LeCroy) hCMEC/D3 human brain endothelial cell line [31] Abbreviation: ERS, electrical resistance system; EVOM, Epithelial Voltohmmeter; HUVEC, human umbilical vein endothelial cells; iPSC, induced pluripotent stem cell; MEA, multi-electrode array; SC, stem cell; WPI, World Precision Instruments.

Derivative Assay:

Article Title: The Use of Sensors in Blood-Brain Barrier-on-a-Chip Devices: Current Practice and Future Directions.
Article Snippet: A wide range of BBBoCs Biosensors 2023, 13, 357 5 of 17 utilize TEER and EIS sensors for monitoring the overall tightness or disruption of the barrier integrity (Table 1). two-compartment vertical chip 4 Pt film electrodes, custom impedance analyzer with AD5933 chip (Analog Devices) co-culture: primary human brain endothelial cells, pericytes, astrocytes [22,23] two-compartment vertical chip 4 Pt wire electrodes, SP-300 potentiostat (Bio-Logic Science Instruments), HP4194A impedance analyzer (Hewlett Packard) hCMEC/D3 human brain endothelial cell line [24] two-compartment vertical chip 2 Pt wire electrodes, PGSTAT302N potentiostat with FRA32M frequency response analysis module (Metrohm Autolab BV) bEnd.3 mouse brain endothelial cell line [25] two-compartment vertical chip 4 Au film electrodes, PGstat128N (Metrohm Autolab BV) co-culture: human iPSC derived endothelial cell, human brain pericytes, astrocytes [26] two-compartment vertical chip 2 Ag/AgCl wire electrodes, E4980AL/032 LCR meter (Keysight Technologies) co-culture: human iPSC derived endothelial cell, human astrocytes [27] Biosensors 2023, 13, 357 6 of 17 two-compartment vertical chip 4 Pt wire electrodes, HF2IS impedance spectroscope, HF2LI lock-in amplifier (Zurich Instruments) hCMEC/D3 human brain endothelial cell line [28] two-compartment horizontal multiplexed chip (Organoplate) stainless-steel multiplexed pair-electrodes, MI-OT-1 OrganoTEER device (MIMETAS) co-culture: human primary brain endothelial cells, astrocytes, iPSC derived neurons [29] parallel tubular channel horizontal chip 2 wire electrodes, Stingray DS1M12 USB oscilloscope and signal generator (USB Instruments) co-culture: hCMEC/D3 human brain endothelial cell line, human astrocytes [30] Streaming potential two-compartment vertical chip 2 Ag/AgCl wire electrodes, SR560 voltage pre-amplifier (Stanford Research Systems), Wave Ace digital oscilloscope (Teledyne LeCroy) hCMEC/D3 human brain endothelial cell line [31] Abbreviation: ERS, electrical resistance system; EVOM, Epithelial Voltohmmeter; HUVEC, human umbilical vein endothelial cells; iPSC, induced pluripotent stem cell; MEA, multi-electrode array; SC, stem cell; WPI, World Precision Instruments.

Microelectrode Array:

Article Title: The Use of Sensors in Blood-Brain Barrier-on-a-Chip Devices: Current Practice and Future Directions.
Article Snippet: A wide range of BBBoCs Biosensors 2023, 13, 357 5 of 17 utilize TEER and EIS sensors for monitoring the overall tightness or disruption of the barrier integrity (Table 1). two-compartment vertical chip 4 Pt film electrodes, custom impedance analyzer with AD5933 chip (Analog Devices) co-culture: primary human brain endothelial cells, pericytes, astrocytes [22,23] two-compartment vertical chip 4 Pt wire electrodes, SP-300 potentiostat (Bio-Logic Science Instruments), HP4194A impedance analyzer (Hewlett Packard) hCMEC/D3 human brain endothelial cell line [24] two-compartment vertical chip 2 Pt wire electrodes, PGSTAT302N potentiostat with FRA32M frequency response analysis module (Metrohm Autolab BV) bEnd.3 mouse brain endothelial cell line [25] two-compartment vertical chip 4 Au film electrodes, PGstat128N (Metrohm Autolab BV) co-culture: human iPSC derived endothelial cell, human brain pericytes, astrocytes [26] two-compartment vertical chip 2 Ag/AgCl wire electrodes, E4980AL/032 LCR meter (Keysight Technologies) co-culture: human iPSC derived endothelial cell, human astrocytes [27] Biosensors 2023, 13, 357 6 of 17 two-compartment vertical chip 4 Pt wire electrodes, HF2IS impedance spectroscope, HF2LI lock-in amplifier (Zurich Instruments) hCMEC/D3 human brain endothelial cell line [28] two-compartment horizontal multiplexed chip (Organoplate) stainless-steel multiplexed pair-electrodes, MI-OT-1 OrganoTEER device (MIMETAS) co-culture: human primary brain endothelial cells, astrocytes, iPSC derived neurons [29] parallel tubular channel horizontal chip 2 wire electrodes, Stingray DS1M12 USB oscilloscope and signal generator (USB Instruments) co-culture: hCMEC/D3 human brain endothelial cell line, human astrocytes [30] Streaming potential two-compartment vertical chip 2 Ag/AgCl wire electrodes, SR560 voltage pre-amplifier (Stanford Research Systems), Wave Ace digital oscilloscope (Teledyne LeCroy) hCMEC/D3 human brain endothelial cell line [31] Abbreviation: ERS, electrical resistance system; EVOM, Epithelial Voltohmmeter; HUVEC, human umbilical vein endothelial cells; iPSC, induced pluripotent stem cell; MEA, multi-electrode array; SC, stem cell; WPI, World Precision Instruments.



Similar Products

94
RayBiotech inc protein chip array
Protein Chip Array, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/Human+Chemokine+Array+GS1/pmc13378945-39-30-32
Average 94 stars, based on 1 article reviews
protein chip array - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

94
RayBiotech inc mouse inflammation array gs1 antibody chip
Mouse Inflammation Array Gs1 Antibody Chip, supplied by RayBiotech inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/Mouse+Inflammation+Array+GS1/pm42259765-391-7-13
Average 94 stars, based on 1 article reviews
mouse inflammation array gs1 antibody chip - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

86
Mimetas Inc renal chip array
Renal Chip Array, supplied by Mimetas Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/array+chip+renal/pmc12805313-461-3-9
Average 86 stars, based on 1 article reviews
renal chip array - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

95
Randox cytokine chip array kit
Cytokine Chip Array Kit, supplied by Randox, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/CYTOKINE+ARRAY/pm41974355-96-19-25
Average 95 stars, based on 1 article reviews
cytokine chip array kit - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

94
fluidigm dynamic array integrated fluidic circuit ifc chips
Dynamic Array Integrated Fluidic Circuit Ifc Chips, supplied by fluidigm, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/48%2E48+Dynamic+Array+IFC+for+Gene+Expression/pm41866099-141-7-22
Average 94 stars, based on 1 article reviews
dynamic array integrated fluidic circuit ifc chips - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

99
HORIBA Ltd microfluidic static droplet array chip
Microfluidic Static Droplet Array Chip, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/LabRAM+Odyssey/pm41833413-52-5-19
Average 99 stars, based on 1 article reviews
microfluidic static droplet array chip - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

94
fluidigm array ifc chip
Array Ifc Chip, supplied by fluidigm, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/48%2E48+Dynamic+Array+IFC+for+Gene+Expression/pmc12858333-209-35-38
Average 94 stars, based on 1 article reviews
array ifc chip - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

95
fluidigm dynamicarray 96 96 chips
Dynamicarray 96 96 Chips, supplied by fluidigm, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/chip+array+assay/96%2E96+Dynamic+Array+IFC+for+Gene+Expression/pm41326455-110-26-29
Average 95 stars, based on 1 article reviews
dynamicarray 96 96 chips - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

Image Search Results